Cabling Categories We Install
Match the right cable category to your bandwidth needs and 10-year roadmap:
- Cat 6: 1 Gbps to 100m, 10 Gbps to 55m. Standard SMB office to desk
- Cat 6a: 10 Gbps to 100m. Mandatory for server uplinks, prosumer offices, future-proofing
- Cat 7 / Cat 8: 10-40 Gbps. Niche use, rare in UAE
- Fibre OM3 / OM4: 10-100 Gbps over 300-550m. Building risers, data centre, multi-floor backbone
- Fibre OS2 single-mode: 100 Gbps+. Inter-building, long-distance
Real Cost Ranges by Office Size
Cabling cost benchmarks from 300+ Dubai office projects:
- Small office (5-25 drops): AED 8,000-18,000
- Mid-office (25-75 drops): AED 18,000-40,000
- Large office (75-200 drops): AED 40,000-95,000
- Enterprise (200-500 drops): AED 95,000-250,000+ with fiber risers
- Cat 6a premium over Cat 6: about 15-20 percent
Fluke Certification Process
Every Azizi Technologies cabling install is tested with a Fluke DSX-5000 or DSX-8000 cable certifier. Tests run per cable: length, attenuation, NEXT (near-end crosstalk), FEXT, return loss, propagation delay - all measured against TIA-568 or ISO 11801 spec. Printed PDF test report becomes part of your network documentation, supporting future warranty claims and audit requirements.
RTA Building Code Compliance
Cables run through common Dubai building areas (corridors, risers, ceiling voids) must be in RTA-approved cable trays with fire-rated jackets. Standard install includes compliant cable trays, fire-stopping where cables cross fire-rated walls, and labelled riser entries. Some Free Zone authorities (DIFC, ADGM, DMCC) require submitted cabling permits which Azizi Technologies handles.
Why Choose Azizi Technologies for Structured Cabling in Dubai
- TIA-568 + ISO 11801 standards compliance
- Fluke DSX-5000 certified terminations
- RTA building code + Free Zone permits handled
- 15-year cable lifespan
- Labelled patch panels + cable maps
- 6-month warranty on cabling work
How Structured Cabling Works in Dubai
Free Site Survey
Cable plan with run lengths, drop locations, riser inspection
Quote + Materials
Itemised AED quote with cable category, drop count, labour
Install + Terminate
Concrete drilling, riser pulls, terminations, patch panel mount
Fluke Test + Document
DSX-5000 certification per cable, printed PDF report, labelled map
Key Benefits of Structured Cabling
- Cat 6 / Cat 6a / fiber options
- Fluke-certified terminations
- TIA-568 / ISO 11801 compliant
- RTA building code aligned
- Labelled patch panels
- 15-20 year lifespan